上(shàng)一(yī)篇:JGH剛(gāng)體滑觸綫--耐(nài)高(gāo)溫 *
下(xià)一篇:ST剛體(tǐ)滑綫
歡迎(yíng)訪問上(shàng)海(hǎi)徐(xú)吉電(diàn)氣有限公司網(wǎng)站

產品型號:
廠商性質:生產廠(chǎng)家(jiā)
所在地(dì):上海(hǎi)市
更(gēng)新(xīn)時間(jiān):2024-01-01
產(chǎn)品簡介:
本目錄是上(shàng)海徐吉電(diàn)氣有限(xiàn)公(gōng)司為您精(jīng)心選(xuǎn)購的:
耐高(gāo)溫(wēn)(剛體(tǐ))鋼體滑(huá)觸綫
一:HXPnL-T,HXPnL-TⅡ,HXPnL-TⅢ係(xì)列(liè)鋼體(tǐ)滑綫(xiàn)由銅導軌,導(dǎo)軌(guǐ)支架,絕(jué)緣(yuán)子組件以及外置(zhì)式集(jí)電(diàn)器(qì)等組(zǔ)件(jiàn)組(zǔ)合(hé)而(ér)成(chéng),由於該產(chǎn)品具有電流大,耐高溫(wēn),抗腐蝕(shí)等特點,因(yīn)此被(bèi)廣泛應用(yòng)於(yú)冶金(jīn),造(zào)船,港(gǎng)口等(děng)行業.
HXPnL-T係列(liè)鋼體滑(huá)綫(xiàn)
HXPnL-T Serise steel collector bar | |||||
型號規(guī)格 Type & spec | 滑觸(chù)綫截麵尺寸(cùn)(mm)Busbar size (mm) | 載流量(A) Current(A) | 適(shì)配(pèi)外置式集電(diàn)器 Suit able current collenctor | ||
| A | B | C | |||
| HXPnL-T-85/300 | 48 | 56 | 13.42 | 300 | TJD-600 |
| HXPnL-T-110/400 | 50 | 56 | 14.11 | 400 | TJD-600 |
| HXPnL-T-170/500 | 55 | 56 | 15.88 | 500 | TJD-600 |
| HXPnL-T-240/700 | 58 | 56 | 16.93 | 700 | TJD-600 |
| HXPnL-T-320/900 | 63 | 56 | 18.7 | 900 | TJD-600 |
| HXPnL-TⅡ-170/1000 | 65 | 80 | 46 | 1000 | TJD-1200 |
| HXPnL-TⅡ-240/1300 | 68 | 80 | 46 | 1300 | TJD-1200 |
| HXPnL-TⅡ-320/1900 | 73 | 80 | 50 | 1900 | TJD-1200 |
注(zhù):滑觸綫(xiàn)標準長度:6m。 Note:standard busbar length 6m. | |||||

一,產(chǎn)品(pǐn)特(tè)點(diǎn)
本產品由梯型銅棒和(hé)槽(cáo)鋼或由“T”型銅排(pái)和(hé)槽(cáo)型鋁(lǚ)結合(hé)相(xiāng)構成(chéng)。用高強(qiáng)度(dù)絕(jué)緣子作支撐,從而(ér)組(zǔ)成向各(gè)種起(qǐ)重(zhòng)機械(xiè)設備(bèi)饋電的移(yí)動滑(huá)觸(chù)綫(xiàn)。本產品有(yǒu)如(rú)下特點(diǎn):
1,運行(háng)可(kě)靠,絕不發生電源(yuán)中斷故(gù)障(zhàng)。
2,可(kě)使用於(yú)高(gāo)溫(wēn),高(gāo)粉塵,高腐(fǔ)蝕(shí)氣體(tǐ)等惡(è)劣環境(jìng)。
3,機械(xiè)強(qiáng)度大,不(bù)易(yì)彎曲變(biàn)形,能耐(nài)受*的(dí)短路(lù)衝擊(jī)電流。
4,可根(gēn)據用戶(hù)需要(yào)設(shè)定載流量,zui大可達(dá)3000A以上(shàng),電壓(yā)等(děng)級(jí)可達(dá)到5KV以上(shàng)。
5,采用(yòng)銅(tóng)或(huò)銅鋁(lǚ)導(dǎo)體(tǐ),可大幅度(dù)降低導綫電(diàn)能(néng)損耗。
6,添(tiān)加(jiā)輔(fǔ)助電纜後(hòu),可組(zǔ)成低(dī)阻抗滑觸(chù)綫,導綫(xiàn)阻(zǔ)抗成倍降低(dī)。
7,布(bù)綫可在上部或(huò)下部滑(huá)觸。
8,JGH-“I”型滑觸綫更有(yǒu)散(sàn)熱(rè)麵特大,結構(gòu)緊(jǐn)湊簡單,安(ān)裝(zhuāng)維(wéi)修方便等優(yōu)點。
二(èr),產(chǎn)品(pǐn)型號(hào)與規格
鋼(gāng)體(tǐ)滑(huá)觸綫型號,規(guī)格(gé)及(jí)額定電(diàn)流(liú)值(zhí)
| 型(xíng)號 | 標(biāo)稱(chēng)截麵 | 額定(dìng)電壓(yā)(A) | 重量(liáng)(Kg/6m) |
| JGH-85 | 85 | 500 | 24.3 |
| JGH-110 | 110 | 600 | 25.9 |
| JGH-170 | 170 | 800 | 29.4 |
| JGH-240 | 240 | 1000 | 46.1 |
| JGH-320 | 320 | 1200 | 50.4 |
| JGH-170Ⅱ | 2x170 | 1300 | 53.9 |
| JGH-240Ⅱ | 2x240 | 1800 | 62.2 |
| JGH-320Ⅱ | 2x320 | 2200 | 68.8 |
| 注:滑(huá)觸(chù)綫標準長度(dù):6m,可根據(jù)用戶需求(qiú)設(shè)置載流(liú)量,zui大可達(dá)3000A以(yǐ)上(shàng)。 | |||
| 型(xíng)號 | 標稱截麵 | 額定(dìng)電壓(A) | 重(zhòng)量(Kg/6m) |
| JGHI-10 | 85 | 500 | 24.3 |
| JGHI-110 | 110 | 600 | 25.9 |
| JGHI-170 | 170 | 800 | 29.4 |
| JGHI-240 | 240 | 1000 | 46.1 |
| JGHI-320 | 320 | 1200 | 50.4 |
| JGHI-170Ⅱ | 2x170 | 1300 | 53.9 |
| JGHI-240Ⅱ | 2x240 | 1800 | 62.2 |
| JGHI-320Ⅱ | 2x320 | 2200 | 68.8 |
鋼(gāng)體(tǐ)滑觸綫一般(bān)情況(kuàng)下按6m定(dìng)尺長(cháng)度(dù)供貨(huò)。
鋼體(tǐ)滑(huá)觸(chù)綫(xiàn)絕緣支架安裝間距(jù)一般為3m
滑(huá)觸綫分(fēn)為單綫式(shì)和雙(shuāng)綫(xiàn)平等(děng)饋(kuì)電式兩種(zhǒng),除雙(shuāng)綫(xiàn)平(píng)等式以(yǐ)JGH-□II表示外,單(dān)綫(xiàn)式不(bù)另加表(biǎo)注(zhù),其斷麵如下:
三(sān),鋼體滑(huá)觸綫(xiàn)係(xì)列配(pèi)套件
D集電(diàn)器
|
四(sì),鋼(gāng)體滑觸(chù)綫的(dí)連(lián)接
滑觸綫的(dí)連(lián)接如下圖所示:
連(lián)接(jiē)時(shí),將兩段支架,通(tōng)過內部的鋼(gāng)芯用螺(luó)栓(shuān)連接,銅導體則(zé)用二塊長夾板,夾緊(jǐn)在(zài)支(zhī)架(jià)上,為了(liǎo)防止(zhǐ)剛(gāng)體(tǐ)因(yīn)溫度(dù)變(biàn)化(huà)引(yǐn)起(qǐ)的膨脹,安裝時在(zài)連(lián)接(jiē)處(chǔ)應(yīng)留有(yǒu)間(jiān)隙(xì),間(jiān)隙的尺(chǐ)寸見(jiàn)下表:
| 工作(zuò)場地的周(zhōu)圍溫(wēn)度 | 30°C | 40°C | 60°C | 70°C |
| 間隙(xì)尺(chǐ)寸 | 3-5mm | 5-7mm | 7-9mm | 10-15mm |
予(yú)留間隙的尺寸跟安裝時(shí)的(dí)環境(jìng)溫度有關,一(yī)般冬(dōng)季安裝(zhuāng)時取高值(zhí),夏天(tiān)安(ān)裝(zhuāng)時取(qǔ)低(dī)值(zhí)。
五(wǔ),滑觸(chù)綫的安裝(zhuāng)
滑(huá)觸綫的安裝方(fāng)式(shì),一般(bān)常用(yòng)的為上(shàng)部(bù)滑(huá)觸(chù)和下部滑(huá)觸二(èr)種(zhǒng),也(yě)可根(gēn)據用戶(hù)要求,采用(yòng)其(qí)它安裝(zhuāng)方式(shì)。
滑觸綫(xiàn)的安裝(zhuāng)支架一般(bān)為3m一個,特殊(shū)情(qíng)況亦可采(cǎi)取加(jiā)強措(cuò)施(shī)適(shì)當(dāng)擴大(dà)距(jù)離,三(sān)根滑觸綫之間的相間(jiān)距離為(wéi)400mm,如為低(dī)阻(zǔ)抗滑觸(chù)綫(xiàn),相間(jiān)距(jù)離(lí)可擴(kuò)大(dà)到450mm。
六(liù),鋼體滑觸(chù)綫(xiàn)的設計(jì)數(shù)據及(jí)計算方(fāng)式(shì)
1,滑觸綫(xiàn)阻抗值及100A-100m時的(dí)綫路電壓降(jiàng)值(zhí)(使(shǐ)用電壓為380V,COS為(wéi)0.8時)
| 滑觸綫(xiàn)規格(gé) mm2 | 相間距離 mm | 在90°C時阻(zǔ)降(jiàng)值Z Ω/Km | 100A-100m時綫路(lù)電壓降(jiàng) | |
| u(V) | u% | |||
| 85 | 200 | 0.3629 | 6.29V | 1.65% |
| 300 | 0.3813 | 6060V | 1.73% | |
| 400 | 0.3946 | 6084V | 1.80% | |
| 110 | 200 | 0.3202 | 5.55V | 1.16% |
| 300 | 0.3404 | 5.90V | 1.55% | |
| 400 | 0.3552 | 6.15V | 1.62% | |
| 170 | 200 | 0.2690 | 4.66V | 1.23% |
| 300 | 0.2915 | 5.05V | 1.33% | |
| 400 | 0.3078 | 5.33V | 1.40% | |
| 240 | 200 | 0.2459 | 4.26V | 1.12% |
| 300 | 0.2716 | 4.70V | 1.24% | |
| 400 | 0.2857 | 4.95V | 1.30% | |
| 320 | 200 | 0.2328 | 4.03V | 1.06% |
| 300 | 0.2596 | 4.50V | 1.18% | |
| 400 | 0.2741 | 4.75V | 1.25% | |
| 2×170 | 200 | 0.2076 | 3.60V | 0.95% |
| 300 | 0.2319 | 4.02V | 1.06% | |
| 400 | 0.2493 | 4.32V | 1.14% | |
| 2×240 | 200 | 0.1976 | 3.42V | 0.90% |
| 300 | 0.2249 | 3.90V | 1.03% | |
| 400 | 0.2416 | 4.19V | 1.10% | |
| 2×320 | 200 | 0.1932 | 3.35V | 0.88% |
| 300 | 0.2178 | 3.77V | 0.99% | |
| 400 | 0.2046 | 4.06V | 1.07% | |
2,滑(huá)觸(chù)綫在(zài)短路(lù)時(shí)耐受電(diàn)流(liú)值(KA)(安裝支架(jià)間距(jù)為(wéi)3m時)
| 滑觸綫(xiàn)規格 mm2 | 滑觸(chù)綫三相平(píng)放時相間(jiān)距(jù)離(lí)為 | 滑(huá)觸綫三(sān)相(xiāng)豎放時(shí)相(xiāng)間距離為 | ||||
| 200mm | 300mm | 400mm | 200mm | 300mm | 400mm | |
| 85 | 22 | 26 | 31 | 29 | 35 | 41 |
| 110 | 23 | 27 | 32 | 30 | 36 | 42 |
| 170 | 25 | 30 | 35 | 32 | 39 | 45 |
| 240 | 41 | >50 | >50 | >50 | >50 | >50 |
| 320 | 43 | |||||
| 2×170 | >50 | |||||
| 2×240 | ||||||
| 2×320 | ||||||
3,鋼體(tǐ)滑觸綫(xiàn)的(dí)撓度量(liáng)(mm)
| 滑(huá)觸綫規(guī)格(gé) mm2 | 滑觸綫三相豎放時,支架(jià)間距離(lí)為 | 滑觸綫三相(xiāng)平放時(shí),支(zhī)架間距離為(wéi) | ||||||
| 2m | 3m | 4m | 5m | 2m | 3m | 4m | 5m | |
| 85 | 0.28 | 1.44 | 4.6 | 11.1 | 0.33 | 1.62 | 5.14 | 12.6 |
| 110 | 0.31 | 1.52 | 4.8 | 11.8 | 0.35 | 1.72 | 5.44 | 13.2 |
| 170 | 0.35 | 1.73 | 5.4 | 13.5 | 0.38 | 1.96 | 6.17 | 15.0 |
| 240 | 0.16 | 0.84 | 2.3 | 5.4 | 0.20 | 1.08 | 3.20 | 7.8 |
| 320 | 0.19 | 0.96 | 2.4 | 5.9 | 0.24 | 1.20 | 3.60 | 8.4 |
| 2×170 | 0.22 | 1.09 | 3.5 | 8.5 | 0.17 | 0.86 | 2.70 | 6.6 |
| 2×240 | 0.16 | 0.79 | 2.5 | 6.1 | 0.22 | 1.12 | 3.50 | 8.5 |
| 2×320 | 0.18 | 0.91 | 2.9 | 7.1 | 0.25 | 1.28 | 4.10 | 10.0 |
4,負(fù)荷電(diàn)流計算(suàn)
滑(huá)觸綫負荷(hé)電流(liú)計算(suàn)方(fāng)法,過(guò)去采用二(èr)項公(gōng)式(shì)計算(suàn)。現介紹國外(wài)多數資料(liào)中(zhōng)采(cǎi)用的(dí)計算(suàn)方式如(rú)下:即(jí)根(gēn)據(jù)起重機上(shàng)安(ān)裝的有可(kě)能同(tóng)時運(yùn)轉的電動機和額定(dìng)電(diàn)流乘(chéng)以暫(zàn)載係數(shù)和多台(tái)起重(zhòng)機的(dí)同時(shí)係數(shù)。
負荷電流(I)=所有工(gōng)作電(diàn)動(dòng)機(jī)額定(dìng)電流(liú)(1H)×暫(zàn)載係數(shù)(FED)×同(tóng)時係數(F)
FED暫載係數(shù)按下(xià)表確定:(多台起(qǐ)重機同時工作係(xì)數(shù):F取0.4-0.7)
| 暫(zàn)載(zǎi)率(ED) | 暫(zàn)載(zǎi)率(shuài)(FED) |
| 100% | 1.00 |
| 80% | 0.90 |
| 60% | 0.78 |
| 50% | 0.71 |
| 40% | 0.63 |
5,滑觸(chù)綫(xiàn)路(lù)的電壓降(jiàng)問題
過去設(shè)計滑(huá)觸綫路時,采用zui大電(diàn)流來(lái)檢(jiǎn)驗電壓(yā)降。即(jí)從低壓屏(píng)上(shàng)的饋電形狀到(dào)滑觸綫取末端(duān),包(bāo)括供(gōng)電電纜在內(nèi)的電壓(yā)降不得超(chāo)過12%,也就(jiù)是(shì)滑(huá)觸(chù)綫和供電綫路當作一(yī)個(gè)整體來(lái)考(kǎo)慮,在滿(mǎn)足電(diàn)壓降(jiàng)的(dí)要(yào)求(qiú)下(xià),務使(shǐ)投資zui少(shǎo)。隨著近年(nián)來引(yǐn)進工程增多,綜合(hé)國(guó)外(wài)資(zī)料,國外一(yī)般都以(yǐ)負(fù)荷(hé)計(jì)算(suàn)電(diàn)流(liú)來(lái)檢驗電壓(yā)降(jiàng),包括供電(diàn)綫(xiàn)路在內(nèi)到滑(huá)觸(chù)綫(xiàn)zui末(mò)的電壓降(jiàng)值不得超過5%。
電壓計(jì)算(suàn)公式(shì):
u=√ 3 × I×I×Z 或 u=√ 3 × I×I×(RCOSρ+XSinΨ)
式中(zhōng): u=電壓降(V), I=負荷(hé)計(jì)算電流(V), R=電(diàn)阻(Ω/km)
X=電感(Ω/km), Z=阻抗(Ω/km), L=滑(huá)觸綫諸(zhū)長度(m)
滑(huá)觸綫計算長度方式:為滑觸(chù)綫(xiàn)全長(m)
在滑觸綫端部供電時(shí):I=L
在滑觸(chù)綫(xiàn)中部供電時:I=L/2
在滑觸(chù)綫兩端(duān)部同(tóng)時供電(diàn)時:I=L/4
在滑(huá)觸綫(xiàn)兩(liǎng)端端(duān)部距(jù)L/6處(chǔ)供電(diàn)時(shí):I=L/6
七(qī),低(dī)阻抗滑觸綫
近(jìn)代(dài)工業中(zhōng),起(qǐ)重機噸位(wèi)日(rì)益增(zēng)大,運行(háng)距離也(yě)愈來愈長,如何處(chǔ)理(lǐ)滑(huá)觸綫上(shàng)的電壓降(jiàng)不超過允許值(zhí)問(wèn)題(tí),需要設計過程中妥(tuǒ)善(shàn)解(jiě)決(jué)。過(guò)去(qù)解(jiě)決電壓(yā)降(jiàng)過大(dà)的方法(fǎ),不外(wài)乎(hū)采(cǎi)用:加大(dà)滑(huá)觸(chù)綫和供(gōng)電綫(xiàn)路的截麵(miàn);增(zēng)加(jiā)滑觸綫上(shàng)的供(gōng)電點(diǎn)數;縮小三(sān)根(gēn)滑觸(chù)綫之(zhī)間的(dí)相間距離等(děng)等,但這些措施(shī)往往收(shōu)效甚微(wēi)或(huò)很(hěn)不(bù)經濟,這是因為滑(huá)觸綫路中的(dí)電(diàn)抗值難以(yǐ)降(jiàng)低,所以(yǐ)首先(xiān)要解決(jué)如何減少(shǎo)滑(huá)觸綫路(lù)上(shàng)的電抗(kàng)值著手。本廠同有(yǒu)關設(shè)計單位(wèi)一(yī)起(qǐ),研究國外資料,在(zài)剛(gāng)體滑(huá)觸綫上的基(jī)礎上,添加兩根(gēn)輔(fǔ)助(zhù)電纜(lǎn),組成(chéng)低阻(zǔ)抗滑觸(chù)綫後,可(kě)使(shǐ)綫(xiàn)路(lù)阻(zǔ)抗(kàng)值成倍地降低(dī)(根據不同(tóng)規(guī)格(gé)的(dí)剛(gāng)體添(tiān)加(jiā)不同截(jié)麵的(dí)電(diàn)纜(lǎn)後,其阻抗(kàng)值可(kě)以降低到原來(lái)的(dí)1/2-1/3)
上(shàng)一(yī)篇:JGH剛(gāng)體滑觸綫--耐(nài)高(gāo)溫 *
下(xià)一篇:ST剛體(tǐ)滑綫